Pressure and Temperature Sensor with Digital Display
RS WA30 Series
RS WA30 is available with a local pressure and temperature display or a cable output for water networks, fire-water systems and outdoor monitoring. Match ingress protection to the pressure reference, connector and complete assembly.
Applications:
Product Highlights:

Specifications
| Parameter | Specification and conditions |
|---|---|
| Series | RS WA30 display / cable-output versions |
| Nominal full-scale ranges | 1 / 2 / 5 / 10 / 20 / 30 bar |
| Output | 0.5–4.5 V, 0.5–2.5 V, 4–20 mA; confirm supply, protocol and data for the ordered RS485 version |
| Pressure TEB | ≤±0.50% FS at −20 to 85 °C; default elevation 0–100 m; confirm field configuration for other elevations |
| Pressure display accuracy | ±0.2% at −20 to 85 °C, excluding transducer output error |
| Temperature display accuracy | ≤±2 °C for the display version |
| Ambient operating temperature | −40 to 85 °C |
| Media temperature | −40 to 125 °C |
| Response time | As fast as 0.5 ms, depending on configuration |
| Supply, display version | Voltage output: 5–12 VDC; 4–20 mA output: 18–28 VDC |
| Supply, cable version | 0.5–4.5 V output: 5.0 VDC ±5%; 0.5–2.5 V output: 3.3–5 VDC; 4–20 mA output: 8–30 VDC |
| Static overload pressure | 1 / 2 / 5 / 10 / 20 / 30 bar ranges: 10 / 10 / 25 / 50 / 100 / 150 bar respectively |
| Ingress protection | Gauge IP67; absolute / sealed gauge with M12 waterproof cable can achieve IP68 with the matching complete assembly and environment |