RS PM400-E Analog Output Pressure Transmitter

RS PM400-E combines MEMS piezoresistive sensing with digital compensation and calibration for continuous industrial pressure measurement. Choose a voltage or 4–20 mA output. The 22 A/F body offers standard ranges of 100, 160, 250 and 400 bar.

  • Standard ranges: 100 / 160 / 250 / 400 bar
  • Pressure reference: Sealed gauge or absolute
  • TEB at −20 to 85 °C: typical ≤±0.25% FS; maximum ≤±0.50% FS.

Applications and selection

For analog signal acquisition in industrial equipment, fluid-pressure monitoring and process control. Match the range and pressure reference first, then check the output, power supply, medium compatibility, thread seal and electrical connector. For pulsating or transient pressure, check the buffer configuration and the overload limit for that range.

Product features

  • Evaluate accuracy across temperature: digital compensation and calibration control the total error band over the specified temperature range.
  • Match the control system: select a ratiometric voltage, absolute voltage or 4–20 mA output and use the corresponding supply voltage below.
  • Fit the installation: a 22 A/F body and welded SUS316L wetted parts. Confirm material compatibility with the actual medium.
  • Diagnostics and zero adjustment: fault diagnostics are provided; field zero-offset adjustment requires a separate Rodee programming tool.
  • Account for pressure transients: a pressure-buffer configuration is available. Overload and burst limits depend on the range and are not continuous working-pressure ratings.

View datasheet (PDF) · Download PDF

RS PM400-E analog output pressure transmitter

Specifications

ParameterSpecification and conditions
Product seriesRS PM400-E
Standard full-scale ranges100 / 160 / 250 / 400 bar
Pressure referenceSealed gauge or absolute
TEB (−20 to 85 °C)Typical ≤±0.25% FS; maximum ≤±0.50% FS
Media and ambient operating temperature−40–125 °C
Response time, voltage outputs2 ms; a <1 ms version is available on request
Long-term stability≤0.10% FS/year; this is not a room-temperature accuracy rating
Durability>10 million cycles at 10–90% FS
Wetted materialSUS316L stainless steel, welded seal
Body size22 A/F
Ingress protectionIP68 for sealed gauge/absolute; subject to the matching connector, sealing and complete assembly

TEB is the total error band and includes nonlinearity, hysteresis, repeatability and thermal effects. Confirm other temperature bands for this model’s calibration configuration.

Output and supply matching

Output signalOutput typeSupply requirement
0.5–4.5 VRatiometric voltage5.0 VDC ±5%
0.5–2.5 VAbsolute voltage3.2–5 VDC
0–5 V / 1–5 VAbsolute voltage9–30 VDC
0–10 V / 1–10 VAbsolute voltage21–30 VDC
4–20 mACurrent9–32 VDC; 24 VDC recommended

Static overload and burst pressure

Nominal full scaleStatic overload pressureBurst pressure
100 bar500 bar600 bar
160 bar500 bar800 bar
250 bar750 bar800 bar
400 bar800 bar1200 bar

Check the limit for the selected full-scale range. Neither overload pressure nor burst pressure is a normal operating-pressure rating.

Connections, wiring and installation

Pressure-connection options include G1/4 A face seal, G1/4 A O-ring seal, 1/4-18 NPT, 7/16-20 UNF and M12×1.5. Electrical options include M12×1, Metri-Pack and DIN EN 175301-803-A. Pin assignments vary by output and connector: check this model’s dimensions, wiring and ordering code before installation.

Selection and enquiry

Send the medium, pressure range, operating temperature, output and supply, pressure connection, electrical connector and quantity so we can check the configuration. The matching datasheet provides dimensions, wiring and ordering codes.

Ask about configuration →

Datasheet revision: 2024-08-05; bilingual Chinese/English PDF.