RS PM160-E Analog Output Pressure Transmitter

RS PM160-E combines MEMS piezoresistive sensing with digital compensation and calibration for continuous industrial pressure measurement. Choose a voltage or 4–20 mA output. The compact 19 A/F body covers standard ranges from 0.1 to 160 bar.

  • Standard ranges: 0.1 / 1 / 2 / 5 / 10 / 16 / 20 / 30 / 40 / 60 / 100 / 160 bar
  • Pressure reference: Gauge (relative), sealed gauge or absolute
  • TEB: typical ≤±0.25% FS, maximum ≤±0.50% FS at −20 to 85 °C; typical ≤±1.0% FS, maximum ≤±1.2% FS at −40 to 125 °C.

Applications and selection

For analog signal acquisition in industrial equipment, fluid-pressure monitoring and process control. Match the range and pressure reference first, then check the output, power supply, medium compatibility, thread seal and electrical connector. For pulsating or transient pressure, check the buffer configuration and the overload limit for that range.

Product features

  • Evaluate accuracy across temperature: digital compensation and calibration control the total error band over the specified temperature range.
  • Match the control system: select a ratiometric voltage, absolute voltage or 4–20 mA output and use the corresponding supply voltage below.
  • Fit the installation: a 19 A/F body and welded SUS316L wetted parts. Confirm material compatibility with the actual medium.
  • Diagnostics and zero adjustment: fault diagnostics are provided; field zero-offset adjustment requires a separate Rodee programming tool.
  • Account for pressure transients: a pressure-buffer configuration is available. Overload and burst limits depend on the range and are not continuous working-pressure ratings.

View datasheet (PDF) · Download PDF
User manual (Chinese PDF, cable/M12) Download PDF

RS PM160-E analog output pressure transmitter

Specifications

ParameterSpecification and conditions
Product seriesRS PM160-E
Standard full-scale ranges0.1 / 1 / 2 / 5 / 10 / 16 / 20 / 30 / 40 / 60 / 100 / 160 bar
Pressure referenceGauge (relative), sealed gauge or absolute
TEB (total error band)−20 to 85 °C: typical ≤±0.25% FS, maximum ≤±0.50% FS; −40 to 125 °C: typical ≤±1.0% FS, maximum ≤±1.2% FS
Media and ambient operating temperature−40–125 °C
Response time, voltage outputs0.5 ms (voltage outputs)
Long-term stability≤0.10% FS/year; this is not a room-temperature accuracy rating
Durability>10 million cycles at 10–90% FS
Wetted materialSUS316L stainless steel, welded seal
Body size19 A/F
Ingress protectionIP67 for relative gauge; IP68 for sealed gauge/absolute; subject to the matching connector, sealing and complete assembly

TEB is the total error band and includes nonlinearity, hysteresis, repeatability and thermal effects. Select the applicable typical and maximum values for the actual operating temperature range.

Output and supply matching

Output signalOutput typeSupply requirement
0.5–4.5 VRatiometric voltage5.0 VDC ±5%
0.5–2.5 VAbsolute voltage3.2–5 VDC
0–5 V / 1–5 VAbsolute voltage9–30 VDC
0–10 V / 1–10 VAbsolute voltage21–30 VDC
4–20 mACurrent9–32 VDC; 24 VDC recommended

Static overload and burst pressure

Nominal full scaleStatic overload pressureBurst pressure
1 bar5 bar50 bar
2 bar10 bar100 bar
5 bar25 bar100 bar
10 bar40 bar100 bar
16 bar60 bar100 bar
20 bar60 bar300 bar
30 bar120 bar300 bar
40 bar160 bar300 bar
60 bar180 bar300 bar
100 bar300 bar400 bar
160 bar480 bar700 bar

The table lists pressure limits for the 1–160 bar ranges. Confirm the overload and burst ratings separately for the 0.1 bar version. Neither overload nor burst pressure is a normal operating-pressure rating.

Connections, wiring and installation

Pressure-connection options include G1/4 A face seal, G1/4 A O-ring seal, 1/4-18 NPT, 7/16-20 UNF and M12×1.5. Electrical options include M12×1, Metri-Pack and DIN EN 175301-803-A. Pin assignments vary by output and connector: check this model’s dimensions, wiring and ordering code before installation.

Selection and enquiry

Send the medium, pressure range, operating temperature, output and supply, pressure connection, electrical connector and quantity so we can check the configuration. The matching datasheet provides dimensions, wiring and ordering codes.

Ask about configuration →

Datasheet revision: 2026-08-21; bilingual Chinese/English PDF.