Pressure Transmitter (Digital Output)
RS PM160-DV Series
RS PM160-DV is a low-power MEMS piezoresistive pressure and temperature sensor with digital compensation, calibration and fault diagnostics. I²C and SPI configurations are available. Range options include vacuum and low pressure up to 160 bar, with relative gauge, sealed gauge or absolute pressure references. Cable versions can provide I²C plus analog voltage.
Features & Applications:
The PM160-DV series is digitally compensated and calibrated, with I2C and SPI digital output for pressure and temperature:
TEB for ranges >2 bar: typical ≤±0.25% FS and maximum ≤±0.50% FS at −20 to 85 °C. Confirm TEB separately for ranges ≤2 bar.
I2C and SPI digital output for both pressure and temperature.
Fault diagnostics support low-power pressure and media-temperature acquisition. Field zero adjustment requires a separate Rodee programming tool.
Media-contacting parts are made of SUS316L stainless steel and sealed by welding, with an optional built-in pulsation pressure buffer to ensure reliability and durability. The series offers IP67 or IP68 ingress protection as well as EMI protection, and suits most application environments.
Product Highlights:
View datasheet (PDF) · Download PDF
User manual (Chinese PDF, cable/M12) Download PDF

Specifications
| Parameter | Specification and conditions |
|---|---|
| Series | RS PM160-DV digital pressure and temperature sensor |
| Range selection | Vacuum, low-pressure and full-scale options up to 160 bar; ranges depend on pressure reference |
| Pressure reference | Relative gauge / sealed gauge / absolute |
| Output | I²C / SPI digital pressure and temperature; optional I²C plus voltage on cable versions; SPI is not available with M12 |
| TEB (ranges >2 bar) | Typical ≤±0.25% FS, maximum ≤±0.50% FS at −20 to 85 °C |
| Low-pressure TEB (ranges ≤2 bar) | Confirm the selected low-pressure range; do not apply the high-range TEB directly |
| Supply | 3.0–5.5 VDC; match supply and pull-ups to the 3.3 V or 5 V version; no built-in level shifting |
| Response time | Maximum 2.5 ms; a 0.8 ms version is available on request |
| Temperature measurement range | Pressure full scale >2 bar: −20 to 80 °C; ≤2 bar: −10 to 70 °C; measures media temperature |
| Operating temperature | M12 or Teflon-wire versions: −40 to 125 °C; standard ribbon cable: −20 to 85 °C |
| Ingress protection | Gauge IP67; absolute / sealed gauge with M12 can achieve IP68 with the matching complete assembly |
| Wetted material | SUS316L stainless steel |
| Datasheet version | 2025-11-02, 6 pages |